BitScope BS300U

USB BitScope 300 (Replaced by BS310)
USB BitScope 300
Next Item Prev Item Product Summary
Order Code BS300U
Description 100 MHz analog + 8 logic, 40 MS/s A/D, 32 kB x 2 buffer, 1.25 Mb/s BNA-03 USB plus wavegen option
Comment Replaced by BS310.
Price
Quantity USD (US Dollar)
1+ $ 495.00

Product Information

The BS300U model has been superceded by BS325U.

BS325N offers new features and improved performance but remains compatible with BS300U.

This is our USB mixed mode digital oscilloscope, logic analyzer and data acquisition device.

This unit has been superceeded by the new BS310U.

Analog Inputs [1] 2 x BNC + 2 x POD
Logic Inputs 8 x POD
Analog Bandwidth [2] 100 MHz
Converter Bandwidth [3] 75 ~ 100 MHz
Input Impedance 1M/20 pF (standard oscilloscope)
Input Voltage Range (+/-) 262mV ~ 5.52V (x1) & 2.6V ~ 55.2V (x10)
Analog Sensitivity 2mV ~ 50mV
Maximum Sensitivity [4] 300 uV
Fast Sample Rates 4, 5, 10, 13.5, 20, 25, 33, 40 MS/s
Slow Sample Rates [5] 4 kHz ~ 1 MHz (slow) & <1 Hz (burst mode)
Channel Buffer Depth 32 kS x 2 (analog and digital)
Resolution (Converter) TLC5540 8 bit converter with 6.8 ~ 7.6 ENOB
Maximum Resolution [6] 11.5 ENOB
Glitch Capture 25 nS
BitScope Digital Trigger 8 bit combinatorial on logic or A/D output.
High Speed Analog Trigger YES
Waveform Generator [7] 10 MS/s (switchable through BNC Channel B)
Analog Interface 2 x BNC and 2 x POD
Logic Interface 1 x DB25 (inc. logic, analog, data and power)
Data Upload Speed (Max) 1.25 Mb/s
Other Interface Options [8] Ethernet, RS-232
Standard PC Software BitScope DSO
Power Requirement [9] 12VDC 500 mA
Operating Temperature 0ºC to 50ºC
Storage Temperature -20°C to +60°C
Size (WxHxD) 150x55x170 mm
[1] Analog capture for both channels is selectable from BNC or POD inputs.
[2] Input bandwidth refers to the bandwidth of the analog input circuitry.
[3] The A/D converter module bandwidth is 75 MHz. BS300 includes compensation for this converter to achieve 100 MHz bandwidth throughout.
[4] Specifies minimum viewable voltage with resolution enhancement.
[5] In addition to the fast sample rates, a wide range of "slow clock" and "burst clock" rates are supported (to below 1 Hz). Burst clocking also supports further increased bit resolution (ENOB).
[6] Specifies the maximum effective number of bits (ENOB) achieveable with resolution enhancement enabled.
[7] The waveform generator is now included as standard with BS300U.
[8] Includes BNA-03 USB adaptor and cable as standard.
[9] Includes UPP-02 Universal AC adaptor and US power cable as standard.

Analog and logic probes are sold seperately.