Product Summary
|
Order Code |
BS300N
|
Description |
100 MHz analog + 8 logic, 40 MS/s A/D, 64 kB buffer, 625 kb/s BNA-01 ethernet, built-in AWG |
Comment |
Internet Enabled. |
Price |
|
Product Information
The BS300N model has been superceded by BS325N.
BS325N offers new features and improved performance but remains compatible with BS300N.
This is our network mixed mode digital oscilloscope, logic analyzer and data acquisition device.
Based on the original BS300 design, this scope is for those who need BitScope Networking.
If you don't need networking we recommend BS310U.
Analog Inputs [1] |
2 x BNC + 2 x POD |
Logic Inputs |
8 x POD |
Analog Bandwidth [2] |
100 MHz |
Converter Bandwidth [3] |
75 ~ 100 MHz |
Input Impedance |
1M/20 pF (BNC), 100K/5 pF (POD) |
Input Voltage Range (+/-) |
262mV ~ 5.52V & 2.6V ~ 55.2V (with x10 probe) |
Input Multipler Gain |
NO |
Analog Sensitivity |
2mV ~ 50mV (x1) |
Maximum Sensitivity [4] |
1 mV (Time), 300uV (Freq), 100uV (Mean) |
Fast Sample Rates |
4, 5, 10, 13.5, 20, 25, 33, 40 MS/s |
Slow Sample Rates [5] |
4 kHz ~ 1 MHz (slow) & <1 Hz (burst mode) |
Channel Buffer Depth |
32 kS (analog), 32 kS (logic) |
Resolution (Converter) |
TLC5540 8 bit converter with 6.8 ~ 7.6 ENOB |
Maximum Resolution [6] |
11.5 ENOB |
Glitch Capture |
25 nS |
BitScope Digital Trigger |
8 bit combinatorial on logic or A/D output. |
High Speed Analog Trigger |
YES |
Waveform Generator [7] |
10 MS/s (switchable through BNC Channel B) |
Analog Interface |
2 x BNC and 2 x POD |
Logic Interface |
1 x DB25 (inc. logic, analog, data and power) |
Data Upload Speed (Max) |
625 kb/s |
Other Interface Options [8] |
USB, RS-232 |
Standard PC Software |
BitScope DSO |
Power Requirement [9] |
12VDC 500 mA |
Operating Temperature |
0ºC to 50ºC |
Storage Temperature |
-20°C to +60°C |
Size (WxHxD) |
150x55x170 mm |
[1] | Analog capture for both channels is selectable from BNC or POD inputs. |
[2] | Input bandwidth refers to the bandwidth of the analog input circuitry. |
[3] | The A/D converter module bandwidth is 75 MHz. BS300 includes compensation for this converter
to achieve 100 MHz bandwidth throughout. |
[4] | Specifies minimum measurable peak-to-peak sinusoidal waveform voltage when both resolution enhancement
and input multiplier are enabled, when viewed as a waveform (Time) or viewed as a spectrum (Freq), and the minimum measurable average DC voltage
(Mean). |
[5] | In addition to the fast sample rates, a wide range of "slow clock" and "burst clock" rates are supported (to
below 1 Hz). Burst clocking also supports further increased bit resolution (ENOB). |
[6] | Specifies the maximum effective number of bits (ENOB) achieveable with resolution enhancement enabled. |
[7] | The waveform generator is now included as standard with BS300N. |
[8] | Includes BNA-01 Network adaptor and cable as standard. |
[9] | Includes UPP-02 Universal AC adaptor and US power cable as standard. |
Analog and logic probes are sold seperately.
|